AMC3330DWER +/-1-V input precision reinforced isolated amplifier with integrated DC/DC converter and high CMTI 16-SOIC -40 to 125
♠ Specifications
Product Attribute | Attribute Value |
Manufacturer: | Texas Instruments |
Product Category: | Isolation Amplifiers |
Series: | AMC3330 |
Minimum Operating Temperature: | - 40 C |
Maximum Operating Temperature: | + 125 C |
Packaging: | Reel |
Brand: | Texas Instruments |
Moisture Sensitive: | Yes |
Product: | Isolation Amplifiers |
Product Type: | Isolation Amplifiers |
Factory Pack Quantity: | 2000 |
Subcategory: | Amplifier ICs |
♠ Product Description
The AMC3330 is a precision, isolated amplifier with a fully integrated, isolated DC/DC converter that allows single-supply operation from the low-side of the device. The reinforced capacitive isolation barrier is certified according to VDE V 0884-11 and UL1577 and separates sections of the system that operate on different common-mode voltage levels and protects low-voltage domains from damage.
The input of the AMC3330 is optimized for direct connection to high-impedance, voltage-signal sources such as a resistor-divider network to sense highvoltage signals. The integrated isolated DC/DC converter allows measurement of non-groundreferenced signals and makes the device a unique solution for noisy, space-constrained applications.
The excellent performance of the device supports accurate voltage monitoring and control. The integrated DC/DC converter fault-detection and diagnostic output pin of the AMC3330 simplify system-level design and diagnostics.
The AMC3330 is specified over the temperature range of –40°C to +125°C.
• 3.3-V or 5-V single supply operation with integrated DC/DC converter
• ±1-V input voltage range optimized for voltage measurements with high input impedance
• Fixed gain: 2.0
• Low DC errors:
– Gain error: ±0.2% (max)
– Gain drift: ±45 ppm/°C (max)
– Offset error: ±0.3 mV (max)
– Offset drift: ±4 µV/°C (max)
– Nonlinearity: ±0.02% (max)
• High CMTI: 85 kV/µs (min)
• System-level diagnostic features
• Safety-related certifications:
– 6000-VPK reinforced isolation per DIN VDE V 0884-11 (VDE V 0884-11): 2017-01
– 4250-VRMS isolation for 1 minute per UL1577
• Meets CISPR-11 and CISPR-25 EMI standards
• Isolated voltage sensing in:
– Motor drives
– Photovoltaic inverters
– Power delivery systems
– Electricity meters
– Protection relays